Features
Portable and lightweight PAD weighs only 2.4 pounds.
Provides the highest level of protection against dust and water for ruggedness in the field.
Utilizes proprietary electrode and biphasic technology in an escalating, low-energy waveform that automatically adjusts for difference in patient impedance.
User-friendly design provides visual and voice prompts to guide the rescuer during the resuscitation process, including CPR.
By just pressing two buttons, the HeartSine samaritan PAD offers simple, straightforward operation.
System Ready indicator flashes to show that the AED is ready for use.
Device automatically runs a self-check protocol each week.
Innovative Pad-Pak? integrated battery and single-use electrode cartridge are replaced at the same time, every four years.
HeartSine Samaritan PAD 350P AED
Portable, rugged defibrillator weighs less than three pounds
The HeartSine? Samaritan? PAD is an easy-to-use, portable Automated External Defibrillator (AED) that provides guided resuscitation. The AED comes with the highest dust and water protection, ensuring the unit will be ready for use in any emergency. The Pad-Pak? integrated battery and electrode single-use cartridge can be replaced at the same time every four years, an easy and cost-saving alternative to most AED?s on the market.
For more information on the HeartSine? Samaritan? PAD 350P AED, available through Avante Health Solutions, contact an Avante representative today.
Physical
Size: 8.0 in x 7.25 in x 1.9 in
Weight: 2.4 lbs
Defibrillator
Waveform: Self-Compensating Output Pulse Envelope (SCOPE) optimized biphasic escalating waveform compensates energy, slope and duration for patient impedance
Warranty: 8-year limited warranty
Patient Analysis System
Method: Evaluates patient?s ECG, signal quality, electrode contact integrity and patient impedance to determine if defibrillation is required
Sensitivity/Specificity: Meets IEC/EN 60601-2-4
Impedance Range: 20 – 230 ohms
Environmental
Operating/Standby Temperature: 32?F to 122?F
Transportation Temperature: 14?F to 122?F for up to two days. If the device has been stored below 32?F, it should be returned to an ambient temperature of between 32?F to 122?F for at least 24 hours before use
Relative Humidity: 5% to 95% (non-condensing)
Enclosure: IEC/EN 60529 IP56
Altitude: 0 to 15,000 ft
Energy Selection
Pad-Pak: Shock 1: 150J | Shock 2: 150J | Shock 3: 200J
Pediatric-Pak: Shock 1: 50J | Shock 2: 50J | Shock 3: 50J
Charging Time
New Battery: Typically 150J in < 8 seconds, 200J in < 12 seconds